57 (Advanced) MU List Management
Examples
& Name them
& Display the saved names
Transmit:
T 3 01 00000008 0131<CR>
This T 3 command will register the MU with ID
00000008 on MU list position 01. The last
parameter shows that it is a Double MU with 2
buttons, which works in zone 4 and as Double
Delegate (DDelL, DDelR).
Receive:
<CR><LF>
>
Transmit:
t 0 00440041004E<CR>
This t 0 command saves DAN to the string buffer.
Since it is a word with only 3 characters, it is
sufficient to use the first part of the string buffer.
Receive:
<CR><LF>
>
Transmit:
T 1 01<CR>
This T 1 command saves the string buffer DAN to
the LeftName (note, that it is a Double MU) in MU
list position 01.
Receive:
<CR><LF>
>
Transmit:
T 0 01 1<CR>
The T 0 i 1 command displays the LeftName (note,
that it is a Double MU) written to MU list position
01, which was done in the previous step.
Receive:
<CR><LF>
LeftNameL[0x01]
00440041004E0000000000000000000000
00000000000000000000000000<CR><LF>
>
Transmit:
t 0 0041004E0041<CR>
The second t 0 command saves ANA to the string
buffer. Since it is a word with only 3 characters, it
is sufficient to use the first part of the string
buffer.
Receive:
<CR><LF>
>
Transmit:
T 2 01<CR>
This T 2 command saves the string buffer ANA to
the RightName (note, that it is a Double MU) in
MU list position 01.
Receive:
<CR><LF>
>

Related product manuals