58 (Advanced) MU List Management
5.3 T A, T E and T F command
Save/Load MU list
All operations on the MU list are executed within temporary memory. Therefore it is
necessary to manually save the list when shutting down the device. When switching on,
the saved MU list is automatically loaded. The saved MU list can nevertheless be
restored manually if needed as the following commands show.
Communication direction
Controller -> CU
Syntax
Description
T A
Restore saved MU list
T E
Clear saved MU list
T F
Save MU list
Note
It is recommended to save the MU list data as soon as important steps in the
configuration are reached. The MU list is never saved automatically without the T F
command.
Transmit:
T 0 01 3<CR>
The T 0 i 3 command displays the RightName (note,
that it is a Double MU) written to MU list position 01,
which was done in the previous step.
Receive:
<CR><LF>
RightNameL[0x01]
0041004E0041000000000000000000
000000000000000000000000000000
<CR><LF>
>