79 Microphone Mode Commands
Example
Parameters
Description
muad
MU ID
[range: 0x00000001 0xFFFFFFFF]
Communication direction
Controller -> CU -> MU
Syntax
Description
~E 2B v
Set MU individual persistent volume
Wireless Write the value v at register 0x2B
Parameters
Description
v
Volume
[range: 0x00 0x32]
(The higher the number, the lower the volume.)
Set a persistent Volume to a specific MU
Transmit:
M 281<CR>
This command sets the MU with the MU ID 0x281 as
receiver of all subsequent commands. Unicast mode
is selected.
Receive:
<CR><LF>
MUAD=0x00000281<CR><CF>
>
Transmit:
~E 2B 15<CR>
This command sets the persistent volume of the MU
that was previously addressed with the M command.
In this example, volume value 0x15 was selected.
Receive:
<CR><LF>
>
Transmit:
M 0<CR>
IMPORTANT:
Switch back to broadcast mode, so that all further
commands address the whole system resp. all MUs.
Receive:
<CR><LF>
MUAD=0x00000000<CR><LF>
>