Function Command text via SMS Note
16
Setting pulse duration password,E,PS,seconds
ex. 1234,E,PS,5 (5 sec pulse duration)
Factory setting:
2 seconds
17
Setting bistable time-delay reply password,E,DS,seconds
ex. 1234,E,DS,10 (10 sec delay)
Factory setting:
20 seconds
18
Checking status in bistable mode Call and hang up before the time-delayed
response set (default 10 sec.)
A response SMS will provide relay status
(ex. “LT ON” or “LT OFF”)
19
Change bistable response text (ON) password,E,T1,new text default response SMS:
“BGates ON” (max 160 characters)
20
Change bistable response text (OFF) password,E,T2,new text default response SMS:
“BGates OFF” (max 160 characters)
1
as stated in the paragraph “Installation” in the section dedicated to the installer, the device can operate in two modes:
- Pulse (default) - the apparatus closes the relay for the number of seconds established (default 2 sec.). Typical applications: gates, armoured doors, etc.
- Bistable - the apparatus closes the relay until the next command. Typical applications: boilers, lights etc.