2.7 Commissioning
!
WARNING
Installation, commissioning and maintenance and repair works should be made by qualied staff.
Any calibration relative to functional aspects of the actuator are preset at the factory, except the
angular stroke setting because for this setting operation, the actuator must be placed on to the valve
(see Section 3.4). Before any modications please contact Bif Italia s.r.l.
Upon actuator commissioning please carry out the following checks:
Check that the pressure and quality of the air supply (ltering degree, dehydration) are as
prescribed. Check that the feed voltage values of the electrical components (solenoid valve
coils, micro-switches, pressure switches, etc.) are as prescribed.
Check that the actuator controls work properly (remote control, local control, emergency
controls, etc.).
Check that the required remote signals (valve position, air pressure, etc.) are correct.
Check that the setting of the components of the actuator control unit (pressure regulator,
pressure switches, ow control valves, etc.) meet the plant requirements.
Check there are no leakages in the pneumatic connections. If necessary, tighten the nuts of
the pipe ttings.
Remove all rust and, in accordance with the applicable painting specications,
repair paint-coat that has been damaged during transport, storage or assembly.
Installation 13
Section 2: Installation

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BIFFI RPS Series and is the answer not in the manual?

BIFFI RPS Series Specifications

General IconGeneral
BrandBIFFI
ModelRPS Series
CategoryController
LanguageEnglish

Related product manuals