EasyManua.ls Logo

Binder BF 400 User Manual

Default Icon
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Issue 05/2016 Art. No. 7001-0081
Operating Manual
BF – Incubators with forced convection
with microprocessor temperature controller
Model Model version Art. No.
BF 53 BF053-230V 9010-0235, 9110-0235
BF 53-UL BF053UL-120V 9010-0236, 9110-0236
BF 115 BF115-230V 9010-0237, 9110-0237
BF 115-UL BF115UL-120V 9010-0238, 9110-0238
BF 240 BF240-230V 9010-0239, 9110-0239
BF 240-UL BF240UL-120V 9010-0240, 9110-0240
BF 400 BF400-230V 9010-0241, 9110-0241
BF 400-UL BF400UL-120V 9010-0242, 9110-0242
BF 720 BF720-230V 9010-0243, 9110-0243
BF 720-UL BF720UL-120V 9010-0244, 9110-0244
BINDER GmbH
Address Post office box 102
D-78502 Tuttlingen
Tel. +49 7462 2005 0
Fax +49 7462 2005 100
Internet http://www.binder-world.com
E-mail info@binder-world.com
Service Hotline +49 7462 2005 555
Service Fax +49 7462 2005 93 555
Service E-Mail service@binder-world.com
Service Hotline USA +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS +7 495 988 15 16

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Binder BF 400 and is the answer not in the manual?

Binder BF 400 Specifications

General IconGeneral
BrandBinder
ModelBF 400
CategoryAccessories
LanguageEnglish

Summary

1. Safety

1.5 General safety instructions on installing and operating the chambers

Provides essential safety guidelines for chamber installation and operation.

1.6 Intended use

Defines the approved applications and limitations for the chamber.

3. Completeness of delivery, transportation, storage, and installation

3.1 Unpacking, and checking equipment and completeness of delivery

Instructions for unpacking and verifying the chamber and accessories.

3.2 Guidelines for safe lifting and transportation

Procedures and precautions for safely moving and transporting the chamber.

3.4 Location of installation and ambient conditions

Specifies suitable installation sites and environmental requirements for operation.

4. Installation of the equipment

4.1 Electrical connection

Details on how to safely connect the chamber to the power supply.

5. Start up

5.1 Turning on the chamber

Step-by-step guide to powering on the chamber for the first time.

6. Controller setting

6.1 Display / entry of temperature and ventilation set-points (without ramp function)

How to set temperature and fan speed without using a ramp function.

6.2 Display / entry of temperature and ventilation set-points (with selected temperature ramp)

Setting temperature and fan speed with an active temperature ramp.

6.3 Time functions: Continuous operation and Timer operation

Explains how to set continuous or timer-based operation modes.

6.4 User level settings

Accessing and modifying advanced controller settings and parameters.

7. Temperature safety device class 3.1 (DIN 12880)

Adjustment

Details on how to properly set and adjust the temperature safety device.

9. Maintenance, cleaning, and service

9.1 Maintenance intervals, service

Recommends regular maintenance schedules and service procedures.

9.2 Cleaning and decontamination

Guidelines for cleaning the chamber to prevent corrosion and maintain hygiene.

10. Disposal

11. Troubleshooting

Temperature Issues

Common temperature-related faults and their solutions.

Controller Issues

Faults related to the controller and display, with troubleshooting steps.

12. Technical description

12.4 Technical data

Comprehensive table of technical specifications for different chamber models.

12.5 Equipment and options (extract)

Lists standard equipment and available optional features for the chambers.

15. Contamination clearance certificate

Related product manuals