Issue 11/2010 Art. No. 7001-0026
Operating Manual
APT.line™ BD (E2)
Incubators with gravity (natural) convection
APT.line™ ED (E2)
Heating ovens with gravity convection
APT.line™ FD (E2)
Heating ovens with forced convection
with R3 Controller
BINDER GmbH
Address Post office box 102
D-78502 Tuttlingen
Tel. +49 7462 2005 0
Fax +49 7462 2005 100
Internet http://www.binder-world.com
E-mail info@binder-world.com
Service Hotline +49 7462 2005 555
Service Fax +49 7462 2005 93 555
Service E-Mail service@binder-world.com
Service Hotline USA +1 866 885 9794 or +1 631 224 4340
Service Hotline Spain +34 9492 677 23
Service Hotline Asia Pacific +852 39070500 or +852 39070503
Service Hotline Russia and CIS +7 495 98815 17

Table of Contents

Questions and Answers

  • L
    Laura HolmesAug 16, 2025
    What to do if my Binder APT.line BD 240 unit has no function?
    • E
      Emily GarzaAug 17, 2025
      If your Binder unit isn't functioning at all, start by checking the power supply connection. If that's okay, inspect the unit fuse and replace it if necessary. If the fuse blows again, contact BINDER service.
  • J
    Joseph StephensonAug 19, 2025
    Why is the set-point temperature not reached in my Binder APT.line BD 240?
    • S
      sharonbrownAug 19, 2025
      If the set-point temperature in your Binder Accessories unit isn't reached after the specified time, make sure the unit door is completely closed. Also, check if the door gasket is defective and replace it if needed. Ensure that the controller is calibrated and adjusted correctly, and verify that the power supply matches the voltage requirements (115V or 230V).
  • B
    Beverly BooneAug 22, 2025
    How to turn on Binder APT.line BD 240 Accessories unit if only the green stand-by LED is lit?
    • J
      Jose ThompsonAug 22, 2025
      If your Binder unit is only showing the green “stand-by” LED, it's likely in stand-by mode. Press and hold the ON/OFF button until the display illuminates.
  • S
    susanmckeeAug 25, 2025
    What to do if temperature is too high and the red alarm pilot lamp is lit in Binder APT.line BD 240?
    • S
      Stephanie RamirezAug 26, 2025
      If the temperature inside the chamber of your BD, option ED, FD Binder Accessories unit is too high and the red alarm pilot lamp of safety device is lit, check the temperature set-point and the safety device class 3.1 settings.
  • K
    Kevin OrtizAug 27, 2025
    What to do if Binder Accessories unit doesn't function and the red alarm pilot lamp is lit?
    • H
      Haley BradleyAug 27, 2025
      If your ED, FD Binder Accessories unit isn't working and the red alarm pilot lamp is lit, the safety device class 2 may have shut down the chamber. Allow the chamber to cool down, then press the RESET button. Check the temperature set-point and the safety device class 2 settings, and select a suitable limit value if necessary.
  • L
    Leslie DominguezAug 30, 2025
    What to do if Binder Accessories chamber doesn’t heat up and the red light is off?
    • M
      maxwellshaneAug 30, 2025
      If the chamber in your Binder Accessories unit isn't heating up, and the red heating control light in the display is not lit but the controller display is working, ensure the timer is correctly programmed or set to continuous operation.
  • J
    Joseph GrahamSep 2, 2025
    Why are there deviations from heating-up times in Binder APT.line BD 240?
    • T
      Taylor ClarkSep 2, 2025
      To address deviations from the indicated heating-up times in your Binder oven, reduce the oven load or allow for longer heating-up times.
  • S
    Steven StephensSep 5, 2025
    Why is my Binder APT.line BD 240 Accessories chamber heating permanently?
    • A
      Annette SimmonsSep 5, 2025
      If the chamber in your Binder Accessories unit is heating permanently and the set-point isn't being held, calibrate and adjust the controller.
  • J
    Joseph KellySep 7, 2025
    Why does the Binder APT.line BD 240 controller return to Normal Display?
    • J
      Jo BrowningSep 7, 2025
      If the controller returns to the Normal Display from any level, repeat entries and enter the values rapidly, because no button was hit for more than 60 sec.
  • D
    Dr. Douglas WangSep 10, 2025
    What to do if fan doesn’t turn in Binder APT.line BD 240?
    • K
      kimberlybensonSep 12, 2025
      If the fan in your FD Binder Accessories unit isn't turning or is turning too slowly, contact BINDER service.

Summary

Safety Instructions and Guidelines

General Installation and Operation Safety

Provides crucial safety guidelines for installation and operation.

Intended Use

Defines the proper use of incubators BD and heating ovens ED/FD.

Unit Description and Overview

Delivery, Transportation, Storage, and Installation

Safe Lifting and Transportation

Safety procedures for moving and transporting the unit.

Equipment Installation

Electrical Connection

Detailed instructions for connecting the unit to the power supply.

Start Up Procedures

Turning On The Unit

Step-by-step guide to powering on the unit.

Controller Setting

Temperature Set-Point Entry

How to set the desired temperature, with or without ramp function.

Safety Devices

Class 2 Safety Device (ED, FD)

Details on the Class 2 safety device for ED and FD units.

Class 3.1 Safety Device (BD)

Details on the Class 3.1 safety device for BD units.

Maintenance, Cleaning, and Service

Cleaning and Decontamination

Procedures for cleaning and decontaminating the unit.

Disposal Procedures

Technical Description

Technical Data and Specifications

Binder APT.line BD 240 Specifications

General IconGeneral
BrandBinder
ModelAPT.line BD 240
CategoryAccessories
LanguageEnglish

Related product manuals