EasyManua.ls Logo

Binder KB 240 (E6) - User Manual

Default Icon
149 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Issue 02/2017 Art. No. 7001-0307
Operating Manual
Translation of the original operating manual
KB (E4), KB (E6)
Cooling Incubators
with compressor technology and program control
Model Model version Art. No.
KB 53 (E4) KB053-230V 9020-0199, 9120-0199
KB 53-UL (E4) KB053UL-120V 9020-0302, 9120-0302
KB 115 (E4) KB115-230V 9020-0397, 9120-0397
KB 115-UL (E4) KB115UL-120V 9020-0398, 9120-0398
KB 240 (E6) KB240-230V 9020-0202, 9120-0202
KB 240-UL (E6) KB240UL-120V 9020-0304, 9120-0304
KB 400 (E6) KB400-230V 9020-0203, 9120-0203
KB 400-UL (E6) KB400UL-120V 9020-0305, 9120-0305
KB 720 (E6) KB720-230V 9020-0204, 9120-0204
KB 720-UL (E6) KB720UL-240V 9020-0306, 9120-0306
BINDER GmbH
Address Post office box 102
78502 Tuttlingen, Germany
Tel. +49 7462 2005 0
Fax +49 7462 2005 100
Internet http://www.binder-world.com
E-mail info@binder-world.com
Service Hotline +49 7462 2005 555
Service Fax +49 7462 2005 93 555
Service E-Mail service@binder-world.com
Service Hotline USA +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS +7 495 98815 16

Table of Contents

Questions and Answers

  • B
    Brenda SalasAug 19, 2025
    What to do if my Binder KB 240 (E6) Accessories chamber has no function?
    • D
      dwarrenAug 19, 2025
      If your Binder Accessories chamber isn't working, start by checking the power supply connection and ensuring it's properly connected. Verify that the voltage matches the required 100-120V or 200-240V. Also, inspect the chamber fuse and replace it if necessary. If the fuse blows again, it's recommended to contact Binder service.
  • A
    Ashley ThomasAug 21, 2025
    Why is my Binder KB 240 (E6) temperature too high with a 'Temp. range' alarm?
    • Q
      qmurphyAug 21, 2025
      If you're getting a 'Temp. range' alarm and the Binder Accessories chamber is overheating, confirm the alarm. The controller might be defective, so contacting Binder service is recommended. Another possible cause is that the controller isn't adjusted correctly, in that case you should calibrate and adjust the controller.
  • S
    Sophia GloverAug 25, 2025
    What to do if my Binder KB 240 (E6) shows "Safety controller over- temperature" alarm?
    • S
      Sara LoveAug 25, 2025
      If you receive a "Safety controller over- temperature" alarm on your Binder Accessories, confirm the alarm. Check the temperature set-point and the safety controller set-point. Adjust to a suitable value if needed. Also, consider if there's too much external heat load and reduce it if possible.
  • A
    Aaron JonesAug 26, 2025
    What to do if my Binder KB 240 (E6) Accessories shows "Safety controller over- temperature" alarm with safety controller class 3.3?
    • V
      vegarachelAug 26, 2025
      If your Binder Accessories is showing a "Safety controller over- temperature" alarm with safety controller class 3.3, confirm the alarm. Verify the temperature set-point and the setting of the over-temperature safety controller, adjusting to a suitable limit value if necessary. Also, check for excessive external heat load and reduce it.
  • L
    Luis StewartAug 28, 2025
    What to do if my Binder Accessories has excess temperature and shows "Temp. range" alarm?
    • A
      andrew97Aug 28, 2025
      If your Binder Accessories displays a "Temp. range" alarm due to excess temperature, confirm the alarm. Ensure the installation site isn't too warm, as an ambient temperature above 25 °C can cause this issue. Select a cooler installation site.
  • K
    Keith HernandezAug 30, 2025
    What to do if my Binder KB 240 (E6) temperature is too low, but the notification "Heating active" is on?
    • Y
      ysmithAug 30, 2025
      If the temperature in your Binder Accessories is too low even though the "Heating active" notification is on, it could be due to a heating defect. In this case, it's best to contact BINDER service for assistance.
  • Z
    zcordovaSep 1, 2025
    Why is my Binder KB 240 (E6) Accessories program duration longer than programmed?
    • A
      Andrea LewisSep 1, 2025
      If the program duration on your Binder Accessories is longer than what you've set, it might be due to inappropriate tolerances programmed. For rapid transition phases, avoid programming tolerance limits to allow for maximum heating speed.
  • X
    xjonesSep 3, 2025
    What to do if my Binder KB 240 (E6) Accessories temperature is too low and deviates from the set-point?
    • L
      luke66Sep 3, 2025
      If your Binder Accessories has a low temperature and triggers a tolerance range alarm, confirm the alarm. Make sure the chamber door is completely closed. If the issue persists, the door gasket might be defective and need replacement. You can also check the controller function, and if necessary, contact BINDER service.
  • A
    Anna VargasSep 5, 2025
    What to do if my Binder Accessories set-point temperature is not reached after specified time?
    • J
      Jennifer KingSep 5, 2025
      If the set-point temperature on your Binder Accessories isn't reached after the specified time, make sure the chamber door is completely closed. If the problem continues, the door gasket may be defective and require replacement. You might also need to calibrate and adjust the controller.
  • A
    Arthur SteinSep 7, 2025
    Why does my Binder KB 240 (E6) Accessories program stop one section too early?
    • M
      Michael HillSep 7, 2025
      If your Binder Accessories program stops one section too early, it could be due to an incomplete program line. When programming with the "ramp" setting, define the end value of the desired cycle by adding an additional section with a section time of at least one minute.

Summary

Safety

General safety instructions on installing and operating the chambers

Provides essential safety guidelines for installation, operation, and general precautions.

Intended use

Outlines the specific applications and intended use of the cooling incubators.

Delivery, Transportation, Storage, and Installation

Location of installation and ambient conditions

Specifies requirements for the installation site and permissible ambient operating conditions.

Installation of the equipment

Electrical connection

Details on connecting the chamber to the power supply, including voltage and fuse information.

Start up

Functional overview of the T4.12 chamber controller

Set-point entry in “Fixed value” operating mode

Time programs

Creating a new time program

Detailed guide on creating custom time programs with sections and parameters.

Week programs

Creating a new week program

Guide to setting up daily temperature programs for a full week.

Key lock

Data transfer via USB interface

Notifications and Alarms

Temperature safety devices

Overtemperature safety controller (temperature safety device class 3.1)

Explains the electronic safety controller for over-temperature protection and its modes.

Over- and undertemperature safety controller (temperature safety device class 3.3) (option)

Details the optional advanced safety controller for both over and under temperature protection.

Defrosting during refrigerating operation

Maintenance, cleaning, and service

Maintenance intervals, service

Guidelines for regular maintenance, service requirements, and warranty voidance.

Cleaning and decontamination

Procedures for cleaning interior and exterior surfaces using recommended agents.

Troubleshooting

Troubleshooting Guide

A table detailing common faults, their possible causes, and required corrective measures.

Technical description

Technical data

Comprehensive table of technical specifications for all chamber models.

Binder KB 240 (E6) Specifications

General IconGeneral
ModelKB 240 (E6)
ColorBlack
Capacity240 sheets
TypeBinder
MaterialCardboard

Related product manuals