EasyManua.ls Logo

Binder KB 23 User Manual

Default Icon
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Issue 02/2019 Art. No. 7001-0177
Operating Manual
Translation of the original operating manual
KB 23 / KB 23-UL (E3.1)
Cooling Incubators
with compressor technology and program control
Model Model version Art. No.
KB 23 (E3.1) KB023-230V 9020-0112, 9120-0112
KB 23-UL (E3.1) KB023UL-115V 9020-0113, 9120-0113
BINDER GmbH
Address: Post office box 102, 78502 Tuttlingen, Germany Phone: +49 7462 2005 0
Fax: +49 7462 2005 100 Internet: http://www.binder-world.com
E-mail: info@binder-world.com Service Hotline: +49 7462 2005 555
Service Fax: +49 7462 2005 93 555 Service E-Mail: service@binder-world.com
Service Hotline USA: +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific: +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS: +7 495 988 15 16

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Binder KB 23 and is the answer not in the manual?

Binder KB 23 Specifications

General IconGeneral
BrandBinder
ModelKB 23
CategoryAccessories
LanguageEnglish

Summary

Safety

General Safety Instructions

Provides essential safety guidelines for chamber installation and operation.

Intended Use

Specifies the intended applications and limitations for the cooling incubators.

Measures to Prevent Accidents

Lists manufacturer's measures to prevent ignition, explosions, and other hazards.

Completeness of Delivery, Transportation, Storage, and Installation

Location of Installation and Ambient Conditions

Specifies requirements for the installation site and environmental conditions.

Electrical Connection

Electrical Connection Details

Details power supply requirements, plugs, and fuses for connection.

Start Up

Settings at the RD3 Program Controller

Guides on initial settings and display modes of the program controller.

Fixed Value Entry Mode

Fixed Value Entry Mode

Explains how to enter set-points for temperature, fan speed, etc.

Week Program Editor

Program Editor

Set-Point Ramp vs. Set-Point Step

Describes methods for programming temperature transitions (Ramp vs. Step).

Programming with Setting "Ramp"

Details programming gradual and sudden temperature changes using ramps.

Set-Point Entry for Program Operation

Guides on entering set-points for program sections.

Program Start Level

Program Start Level

Covers settings for program delay time and number of cycles.

User Level

User Level Settings

Details various controller settings accessible via the user level.

Programming Example: Week Program Editor

Programming Example: Program Editor

Proceeding in Detail

Gives a detailed walkthrough for setting up the program editor example.

Performance in Case of Failures

Temperature Safety Devices

Safety Controller (Temperature Safety Device Class 3.1)

Details the secondary safety controller for over-temperature protection.

Maintenance, Cleaning, and Service

Cleaning and Decontamination

Provides instructions for cleaning and decontaminating the chamber.

Cleaning Procedures

Detailed steps and recommended cleaning agents for the chamber.

Decontamination Procedures

Procedures for decontaminating the chamber after exposure to hazardous substances.

Troubleshooting

Troubleshooting Guide

Lists common faults, possible causes, and required corrective measures.

Related product manuals