EN
No air or fluid supply
Check air and fluid supply ball
valves and supply hoses.
Air piston seal worn. Replace piston seal.
Pilot valve assemblies inoperable.
Switch/interchan
e pilot valves to
isolate faulty pilot valve and
clean/replace.
Main air valve inoperable. Check clean/replace Air valve.
Ball checks not seating correctly.
Inspect, clean and/or replace
balls and seats.
Fault Finding
Symptom Possible Cause Remedy
Pump will not
‘Prime’
Air getting into the suction hose/manifold
Check seals and hose
connections.
Worn piston seal. Replace piston seals.
Ball checks not seating correctly.
Inspect, clean and/or replace
balls and seats.
Check for constant exhaust air when
pump is not running.
Check/replace QE diaphragms.
QE diaphragm defective.
Pump will not run
77-3235 R4.6 15/24 www.carlisleft.com