EasyManua.ls Logo

Binks Maple 30/3 - Technical Specifications

Binks Maple 30/3
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
#
#
Specification
Ratio: 3:1
Maximum air inlet pressure: 7 bar [101.5 psi]
Maximum fluid pressure: 21 bar [304.5 psi]
Nominal flow volume / cycle: 0.75 l/m [0.20 US gal/m]
Output @ 60 cycles / min: 45 l/m [12 US gal/m]
Dirt: 5 microns
Water: -20°C @ 7bar [940ppm]
Compressed Air Inlet 3/8" BSPP / NPSM
A
ir consumption @ 15 cycles/min and 6 bar [87 psi] air inlet
pressure:
Max. Pump Fluid Inlet Pressure
Maximum recommended continous cycle rate:Cycles/min 20
Air volume / cycle @ 3.1 bar/45psi: 9.5 l/m [0.33 SCFM] @ 3.1 bar [45 psi]
1 1/2" Sanitary
Fluid outlet connection: 1 1/2" Sanitary
283 l/m [10 CFM]
A
ir consumption @ 30 cycles/min and 6 bar [87 psi] air inlet
pressure:
595 l/m [20CFM]
EN
Maximum recommended intermittent cycle rate:Cycles/min 40
Fluid inlet connection:
2 bar [30 psi]
A
ir Quality ISO 8573.1 Class 3.3.2
Air volume / cycle @ 6.2 bar/90psi: 18.5 l/m [0.65 SCFM] @ 90 psi [6.2 bar]
Oil: 0.1mg/m³
Weight: 35 kg / 77 lbs
Note:
See Note
Class 3.4.2 Air Quality (Refrigerant dried - water +3ºC@7bar) may be used, however,
above 15 cycles/min optional heavy duty mufflers 192821 or piped exhaust system should
be used, if used continuously.
77-3235 R4.6 4/24 www.carlisleft.com