EN
Set the pump speed to a slow cycle rate and prime the pump to remove any air before increasing
pressure.
A Back Pressure Regulator should be mounted in the paint system return line.
The return line ‘back pressure’ regulator responds to the changes in system fluid flow demand, (due to
variable paint usage) by dynamically adjusting the paint flow rate returning to the system paint tank,
thus maintaining the set pressure.
Set the pump cycle rate to achieve the required paint volume and then adjust the system back
pressure regulator and pump air pressure to achieve the desired system fluid pressure.
Installation
Inspect for any air or fluid leaks.
If an air blow out system is used, never exceed 2 bar [29 psi] on the inlet of the pump.
Exhaust kits are available for these pumps if the air exhaust is required to be piped away from the
pump rather than exhausting locally through the mufflers.