Spectrum Analysis: After most counting functions click on this icon to view a full page display
showing the Spectrum Analysis. You can then adjust ROIs, add ROIs and move a cursor to see
the energy and counts associated with different energies.
Procedure Window. Click on this icon to define the different procedures that you want to use.
An example would be to have different methods of the thyroid uptake stored in memory to be
used for different types of uptake studies.
Isotope Editing: At this page you can bring up the list of factory set isotopes or enter any new
isotopes that you desire. This mode will also allow the efficiency setting for the detectors for
specific isotopes used for Bioassay and Wipe.
Help: This screen will give certain information about using the system.
Screen Tool Bar
The screen tool bar, located at the top of most major screens, features several buttons that standard
conventions in the system and appear on a variety of pages.
Click on <Isotope Editing> in the primary tool bar on the left side of the screen to bring up the Isotope
Editing page. On this page, you can view the screen tool bar and follow along with the descriptions
below.
Open: Click on this button to access a list of the items associated with the current function. For
example, if you are dealing with isotopes, it brings up the isotope list.
Add: This button allows you to add an item to the current operation. For example, on the
isotope page, you can add an isotope. On the patient page, you can add patients.
Edit: This button allows you to go in and edit the item that you are displaying.
Save: Use this option to save any changes or new information that you have entered on the
current page.
Stop/Cancel button will cancel whatever work you were just doing without saving any
changes.
Delete: Use this option to delete information that you have entered. For example, if you entered
a patient and are now finished with that patient, you could delete the patient from the system
memory.
Efficiency: Use this button to enter efficiencies for each isotope associated with wipe and
bioassay.
Close: Select this button to close any current window.
Click on <Close> to return now to the Operation screen.
The Menu Bar
The Menu Bar very top of the desktop screen offers standard Windows functions including File, Record,
View, Window and Help. The system setup and print-setup options are both accessed by selecting <File>
from this menu bar.
File: Under the File screen, the printer set up button allows you to set up the printer that you
are using. The Atomlab 950 uses either DeskJet 694C, 845 or 810C software. The version used is
dependent on the Hewlett Packard printer. We recommend using the 694C printer driver. If a
different printer is being used, follow the instructions for setting up under Windows. The
Database Manager option allows the user to copy or move data. The System Setup button
allows the user to set site information.