| instructions for use, maintenance and installation | version 1.0 July 2017
10
The device operates at 220 V – 50 Hz. Make sure that the electrical cables are not laid under the
boiler, that they are far away from hot surfaces and that they do not touch sharp parts, which could
damage them. If the pellet boiler is under electrical overload, life expectancy of electrical component
greatly reduces.
ATTENTION
Never turn off the boiler by pulling the electrical cable from the socket, while fire is still
burning in the boiler. This could damage the boiler and seriously jeopardize its functioning.
3.2. EXTRACTION OF SMOKE GASES
Extraction of smoke gases must be in accordance with regulations in force. Pipes for smoke gases
must not be connected to other discharge pipes of any other combustion device (figure 2). It is
prohibited to set up extraction of smoke gases into closed and/or semi-closed spaces, e.g. garage,
narrow passages or hallways, underpasses or any other similar spaces. If the flue connection is not
suitable, it must be implemented in accordance with previously provided requirements (point 3.1).
Figure 2
ATTENTION
Extraction of smoke gases must be earthed in accordance with regulations in force. (Earthing
connection is required by law).
Earthing must be independent of combustion unit.
Regarding dimensions and material, from which it is made, the flue pipe must conform to standards
UNI 9615-9731, UNI 10683 - EN1856-1.