Biodom 33
Biodom 33Biodom 33
Biodom 33
|
| |
| instructions for use, maintenance and installation | version 1.0 July 2017
16
The pellet boiler is a combustion device and external surfaces of the boiler can reach higher
temperatures during operation.
The pellet boiler is a C1 class boiler, produced exclusively for burning wood pellets (pellets of 6 mm in
diameter and 30 mm in length with maximum moisture content up to 10 %) or for fuel C1 (wood
pellets) in accordance with standard EN 14961-2.
ATTENTION
DURING PELLET BOILER OPERATION, CHILDREN ARE PROHIBITED TO COME NEAR OR PLAY
WITH IT!
When using a combustion device, it is advisable to take special care of the following:
• during boiler operation DO NOT approach it and do not touch the doors of combustion
chamber, because of DANGER OF BURNS
• during boiler operation DO NOT approach it and do not touch the flue connection, because of
DANGER OF BURNS
• during boiler operation DO NOT perform any kind of cleaning on the combustion device
• during boiler operation do not open the doors of the firebox, because it operates properly
only when its doors are hermetically sealed (if you open the doors during operation, an alarm
will sound)
• during boiler operation DO NOT remove ashes
• DO NOT allow children and animals to come near the pellet boiler
• ADHERE TO REQUIREMENTS SET FORTH IN THIS DOCUMENT
For correct use of the boiler, also heed to the following instructions:
• Use only and exclusively fuel recommended by boiler manufacturer;
• Follow instructions for maintenance;
• Clean the boiler firebox for each pellet container used (3-14 days, when the pellet boiler and
ashes in it are cool);
• DO NOT use the pellet boiler in case of operation malfunction or other irregularities,
abnormal noises and/or suspicious faults and IMMEDIATELY contact authorized service
personnel;
• DO NOT spill water on the boiler, as well as put out fire in the combustion chamber with
water;
• DO NOT lean on the boiler, as it may be unstable and could tip over;
• DO NOT use the pellet boiler as support or a fastening item. Do not leave the container cover
open;
• DO NOT touch the painted surfaces of the boiler during operation;
• DO NOT use wood or charcoal in the pellet boiler, use only pellets with the following
properties:
dimension: diameter 6 mm,