When water temperature in the boiler, even with minimum power, reaches set
temperature, the boiler enters phase COOL FLUID and cools down. The boiler
restarts automatically when the water in the boiler cools down under set value.
Lack of pellets in burning phase
.
Unsuccessful ignition
.
Check boiler status, clean firebox and try to reignite the
boiler.
Thermal
safety activated. Check boiler status and, if no anomalies are
determined, manually reactivate safety and restart the boiler, or contact the
service centre.
Safety pressure control activated. Check boiler status and, if no ano
malies are
determined, restart the boiler, or contact the service centre.
No signal of smoke gases sensor. Contact the service centre
.
No signal of firebox temperature. Contact the service centre
.
No signal of flow sensor or the fans do not operate properly. Contact the service
centre.
Clean the boiler
or flue. In case the alarm is showing again, call service centre.
No signal of water temperature. Contact the service centre
.
Temperatur
e of smoke gases is too high
.