- 9 -
SRP-E300/E302
1-3 Drawer Port
Connect the cash drawer connection cable to the drawer kick-out connector on the rear side
of the printer.
- SRP-E300/E302 - SRP-E300ES/E302ES
Pin No.
Signal Name
Direction
1
Frame Ground
-
2
Drawer Kick-out Drive Signal 1
Output
3
Drawer Open/Close Signal
Input
4
+24V
-
5
Drawer Kick-out Drive Signal 2
Output
6
Signal Ground
-
Caution
- Use a cash drawer that meets the printer specifications.
Using a cash drawer that is inappropriate to the specs or using
it as a power supply for a separate device may result in
damage to the product
- Do not connect a telephone line to the drawer kick-out
connector. Otherwise, the telephone line and the computer
may be damaged.
- Do not allow a foreign object such as a conductor to touch
the cash drawer port. This may result in damage to the product
- Make sure to use a cash drawer with an internal coil resistance of
24 or higher. (The maximum current is 1A.)
- The open signal time for the cash drawer should not exceed 0.8
seconds. After opening the cash drawer, make sure to idle for at
least 3.2 seconds (at least 4 times that of the open signal time)
before operating it.