103
Safety Standard:
Designed in compliance with EN61010-1 (IEC1010-1) for CAT-II 50V,
Pollution Degree II Environment. EMC designed in compliance with
EN61326-1.
Electrical specifications
Accuracy is given as (% of reading + counts of least significant digit) at
23°C ± C, with relative humidity less than 80% R.H.
Capacitance
Range Resolution Accuracy*
Measuring rate as
full scale (approx.)
1000.0 pF
0.1 pF
1% + 10
5 times /sec
10.000 nF
0.001 nF
1% + 5
5 times /sec
100.00 nF
0.01 nF
0.5% + 3
5 times /sec
1000.0 nF
0.1 nF
5 times /sec
10.000 μF
0.001 μF
5 times /sec
100.00 μF
0.01 μF
5 times /sec
1000.0 μF
0.1 μF
0.86 times /sec
10.000 mF
0.001 mF
1% + 5
0.13 times /sec
50.00 mF (890C)
199.99 mF
(830C)
0.01mF 2% + 5
0.026 times /sec
0.006 times /sec
*= The accuracy is specified to measure film capacitor or better, and use
Relative mode to zero residual first.
Notes:
1. Overload protection: 250VR.M.S.