[SOURce:]CURRent:LOW
These commands set the high and low voltage level when the load is in constant current mode.
Command Syntax
[SOURce:]CURRent:HIGH <NRf+>
[SOURce:]CURRent:LOW <NRf+>
Parameters
see specifications for voltage range
Unit
V (volts)
Examples
CURR:HIGH 5
Query Syntax
[SOURce:]CURRent:HIGH? [SOURce:]CURRent:LOW?
Returned Parameters
<NR3>
[SOURce:]VOLTage
This command sets the voltage that the electronic load will regulate when operating in constant
voltage (CV) mode.
Command Syntax
[SOURce:]VOLTage[:LEVel][:IMMediate] <NRf+>
Parameters
See specifications for range
Unit
V (volts)
Examples
VOLT 5
Query Syntax
[SOURce:]VOLTage[:LEVel][:IMMediate]?
Returned Parameters
<NR3>
Related Commands
VOLT:RANG
[SOURce:]VOLTage:RANGe
This command sets the voltage range of the electronic load module. There is only one voltage range.
Command Syntax
[SOURce:] VOLTage:RANGe <NRf+>
Parameters
see specifications for range
Unit
V (volts)
Examples
VOLT:RANG 15
Query Syntax
[SOURce:]VOLTage:RANGe?
Returned Parameters
<NR3>
Related Commands
VOLT
VOLTage:RANGe:AUTO
This command sets the voltage auto range state of the electronic load module.