EasyManuals Logo

BK Precision 8600 Series User Manual

BK Precision 8600 Series
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
53
Examples
VOLT:HIGH 5
Query Syntax
[SOURce:]VOLTage:HIGH?
[SOURce:]VOLTage:LOW?
[SOURce:]VOLTage:TRANsient:MODE
This command selects the operating mode of the transient generator as follows in constant voltage
mode.
CONTinuous The transient generator puts out a continuous pulse stream after receipt of a trigger.
PULSe The transient generator puts out a single pulse upon receipt of a trigger.
TOGGle The transient generator toggles between two levels upon receipt of a trigger.
Command Syntax
[SOURce:]VOLTage:TRANsient:MODE <mode>
Parameters
CONTinuous | PULSe | TOGGle
*RST Value
CONTinuous
Examples
VOLT:TRAN:MODE PULS
Query Syntax
[SOURce:] VOLTage:TRANsient:MODE?
Returned Parameters
<CRD>
Related Commands
VOLT:TRAN:ALEV TRAN
[SOURce:]VOLTage:TRANsient:ALEVel
[SOURce:]VOLTage:TRANsient:BLEVel
These commands specify the transient level of the input voltage. The transient function switches
between level A and level B.
Command Syntax
[SOURce:]VOLTage:TRANsient:ALEVel <NRf+>
[SOURce:]VOLTage:TRANsient:BLEVel <NRf+>
Parameters
0 to max. rated voltage
Unit
V (volts)
Examples
VOLT:TRAN:ALEV 5 VOLT:TRAN:BLEV 0.5
Query Syntax
[SOURce:]VOLTage:TRANsient:ALEVel?
[SOURce:]VOLTage:TRANsient:BLEVel?
Returned Parameters
<NR3>
Related Commands
VOLT
[SOURce:]VOLTage:TRANsient:AWIDth
[SOURce:]VOLTage:TRANsient:BWIDth
This command specifies the transient pulse width of the input voltage.