54
[SOURce:]VOLTage:TRANsient:AWIDth <NRf+>
[SOURce:]VOLTage:TRANsient:BWIDth <NRf+>
VOLT:TRAN:AWID 0.001 VOLT:TRAN:BWID 0.02
[SOURce:] VOLTage:TRANsient:AWIDth?
[SOURce:]VOLTage:TRANsient:BWIDth?
[SOURce:]RESistance
This command sets the resistance of the electronic load when operating in constant resistance mode.
[SOURce:]RESistance[:LEVel][:IMMediate] <NRf+>
0 to max. rated resistance
[SOURce:]RESistance[:LEVel][:IMMediate]?
[SOURce:]RESistance: RANGe
This command sets the resistance range of the electronic load module. This limits the value the
resistance can be set to.
When you program a range value, the electronic load automatically selects the range that corresponds
to the value that you program. If the value falls in a region where ranges overlap, the electronic load
selects the range with the highest resolution.
NOTE: When this command is executed, the IMMediate, TRANsient, TRIGgered, and SLEW resistance
settings are adjusted as follows.
If existing settings are within new range, no adjustment is made.
If existing settings are outside new range, the levels are set to either the maximum or minimum value
of the new range, depending on which they are closest to.