10
SETD<preset0/1/2/3><VOLTAGE>
<CURRENT>[CR]
Return Value: [OK] [CR]
SET preset0/1/2/3 Voltage and Current.
<preset0/1/2/3> =0 preset1
<preset0/1/2/3> =1 preset2
<preset0/1/2/3> =2 preset3
<preset0/1/2/3> =3 Normal Mode
<voltage> = ????
< Current > = ????
Input Command:
SETD 005001000 [CR]
Return Value: [OK] [CR]
Result: Set preset1 voltage
5.00V Current 10.00A
11
GETS<preset0/1/2/3>[CR]
Return Value: <Voltage><Current>[CR]
[OK] [CR]
Get settings of preset0/1/2/3 Volt & Curr
SET preset0/1/2/3 Voltage and Current
<preset0/1/2/3> =0 preset1
<preset0/1/2/3> =1 preset2
<preset0/1/2/3> =2 preset3
<preset0/1/2/3> =3 Normal Mode
<voltage> = ????
< Current >=????
Input Command: GETS0[CR]
Return Value: 05000100[CR] [OK]
[CR]
Result: The Memory preset 1
voltage value is 5.00V and
Current is 1.00A.
12
GABC[CR]
Return Value: < preset0/1/2/3> [CR]
[OK] [CR]
Get preset selection
< preset0/1/2/3> =0 preset1
< preset0/1/2/3> =1 preset2
< preset0/1/2/3> =2 preset3
< preset0/1/2/3> =3 Normal Mode
Input Command: GABC [CR]
Return Value: 0 [CR] [OK] [CR]
Result: Preset Mode is Preset1
13
SABC< preset0/1/2/3>[CR]
Return Value: [OK] [CR]
Set ABC select
< preset0/1/2/3>=0 preset1
< preset0/1/2/3>=1 preset2
< preset0/1/2/3>=2 preset3
< preset0/1/2/3>=3 Normal Mode
Input Command: SABC 2[CR]
Return Value: [OK] [CR]
Result: Preset Mode is set to
Preset3
14
GDLT<{0-5}>[CR]
Return Value: delta time [00-20] [CR]
[OK] [CR]
Get delta time setting value
DeltaTime{0} : Time of Preset1 to Preset2
DeltaTime{1} : Time of Preset2 to Preset1
DeltaTime{2} : Time of Preset1 to Preset3
DeltaTime{3} : Time of Preset3 to Preset1
DeltaTime{4} : Time of Preset2 to Preset3
DeltaTime{5} : Time of Preset3 to Preset2
*Set- DeltaTime <=20S
Input Command: GDLT 0[CR]
Return Value: 10 [CR] [OK] [CR]
Result: DeltaTime[1] is 10S
15
SDLT <location {0-5}; time {00-20}>[CR]
Return Value: [OK] [CR]
Set delta time.
*Set- DeltaTime <=20S
Input Command: SDLT 205[CR]
Return Value: 1 [CR] [OK] [CR]
Result: DeltaTime[3] is set to 20S
16
GSWT<location {0-2}>[CR]
Return Value: SW time [000-600] [CR]
[OK] [CR]
Get SW time
SwTime[1]: Time of Preset1
SwTime[2]: Time of Preset2
SwTime[3]: Time of Preset3
*Set- SwTime <=600S
Input Command: GSWT [CR]
Return Value: 0100 [CR] [OK] [CR]
Result: SwTime[1] is 100S
17
SSWT<location {0-2} time {000-600}>
[CR]
Return Value: [OK] [CR]
Set SW time
*Set- SwTime <=600S
Input Command: SSWT0100[CR]
Return Value: [OK] [CR]
Result: SwTime[0] is set to 100S
18
RUNP< first {0-2}; end {0-2}>[CR]
Return Value: [OK] [CR]
Run SW running
Select what sequence will start running first and
which one will be the last one to be run.
Input Command: RUNP 01[CR]
Return Value: [OK] [CR]
Result: start running SW run A_B

Other manuals for BK Precision 9104

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BK Precision 9104 and is the answer not in the manual?

BK Precision 9104 Specifications

General IconGeneral
BrandBK Precision
Model9104
CategoryPower Supply
LanguageEnglish

Related product manuals