CONFig[SOURce:]VOLTage[:LEVel]:MINimum
This command is used to set the lower limitation (Volt-Min) of the output voltage.
Command syntax: CONFig[SOURce:]VOLTage[:LEVel]:MINimum <NRf>
Parameter: MIN TO MAX|MIN|MAX|
Unit: V
Query syntax: CONFig[SOURce:]VOLTage[:LEVel]:MINimum?
Return parameter: <NRf>
CONFig[SOURce:]VOLTage[:LEVel]:MAXimum
This command is used to set the upper limitation (Volt-Max) of the output voltage.
Command syntax: CONFig[SOURce:]VOLTage[:LEVel]:MAXimum <NRf>
Parameter: MIN TO MAX|MIN|MAX|
Unit: V
Query syntax: CONFig[SOURce:]VOLTage[:LEVel]:MAXimum?
Return parameter: <NRf>
CONFig[SOURce:]FREQuency:MINimum
This command is used to set the lower limitation (Freq-Min) of the output frequency.
Command syntax: CONFig[SOURce:]FREQuency:MINimum <NRf>
Parameter: MIN TO MAX|MIN|MAX|
Unit: Hz
Query syntax: CONFig[SOURce:]FREQuency:MINimum?
Return parameter: <NRf>
CONFig[SOURce:]FREQuency:MAXimum
This command is used to set the upper limitation (Freq-Max) of the output frequency.
Command syntax: CONFig[SOURce:]FREQuency:MAXimum <NRf>
Parameter: MIN TO MAX|MIN|MAX|
Unit: Hz
Query syntax: CONFig[SOURce:]FREQuency:MAXimum?
Return parameter: <NRf>
CONFig:PROTect:CURRent:RMS
This command is used to set the RMS current protection point (Irms-Protect).
Command syntax: CONFig:PROToct:CURRent:RMS <NRf>
Parameter: MIN TO MAX|MIN|MAX|
Unit: A
Query syntax: CONFig:PROToct:CURRent:RMS?
Return parameter: <NRf>
CONFig:PROTect:CURRent:RMS:MODe
This command is used to set the RMS current protection (Irms-Protect) delay mode.
Command syntax: CONFig:PROToct:CURRent:RMS:MODe <NRf>
Parameter: DELay | IMMediate