LIST:STEP:VOLTage
This command is used to edit the voltage level for a single step in the list file.
Command syntaxLIST:STEP:VOLTage <NR1>,<NRf>
Parameter 1: 0 ~ 99
Parameter 2: Voltage, unit: V
Example: LIST:STEP:VOLT 1, 30
Query syntax: LIST:STEP:VOLTage? <NR1>
Query Example: LIST:STEP:VOLT? 1
Return Parameter: <NRf>
LIST:STEP:FREQuency
This command is used to edit the frequency for a single step in the list file.
Command syntaxLIST:STEP: FREQuency <NR1>,<NRf>
Parameter 1: 0 ~ 99
Parameter 2: Frequency, unit: Hz
Example: LIST:STEP:FREQ 2, 60
Query syntax: LIST:STEP: FREQuency? <NR1>
Query Example: LIST:STEP:FREQ? 2
Return Parameter: <NRf>
LIST:STEP:SLOPe
This command is used to edit the slope time for a single step in the list file.
Command syntaxLIST:STEP:SLOPe <NR1>,<NRf>
Parameter 1: 0 ~ 99
Parameter 2: Slope time, unit: s
Example: LIST:STEP:SLOPe 3, 5.5
Query syntax: LIST:STEP:SLOPe? <NR1>
Query Example: LIST:STEP:SLOPe? 3
Return Parameter: <NRf>
LIST:STEP:DWELl:UNIT
This command is used to edit the dwell time units for a single step in the list file.
Command syntaxLIST:STEP:DWELl:UNIT <NR1>,< string >
Parameter 1: 0 ~ 99
Parameter 2: SECond|MINUte|HOUR
Example: LIST:STEP:DWELl:UNIT 2, SEC
Query syntax: LIST:STEP:DWELl:UNIT? <NR1>
Query Example: LIST:STEP:DWELl:UNIT? 3
Return Parameter: <string>
LIST:STEP:DWELl
This command is used to edit the dwell time for a single step in the list file.
Command syntaxLIST:STEP:DWELl <NR1>,<NRf>