Parameter 1: 0 ~ 99
Parameter 2: Dwell time
Example: LIST:STEP:DWELl 3, 20
Query syntax: LIST:STEP:DWELl? <NR1>
Query Example: LIST:STEP:DWEL? 3
Return Parameter: <NRf>
LIST:STEP:SD:STATe
This command is used to enable or disable the disturbance simulation status for a single step in
the list file.
Command syntaxLIST:STEP:SD:STAT <NR1>,<string>
Parameter 1: 0 ~ 99
Parameter 2: DISable|ENABle
Example: LIST:STEP:SD:STAT 3, DIS
Query syntax: LIST:STEP:SD:STAT? <NR1>
Query Example: LIST:STEP:SD:STAT? 2
Return Parameter: <string>
LIST:STEP:SD:CONTinue
This command is used to turn on or off the continuous trigger for disturbance simulation for a
single step in the list file.
Command syntaxLIST:STEP:SD:CONTinue <NR1>,<bool>
Parameter 1: 0 ~ 99
Parameter 2: OFF|ON|0|1
Example: LIST:STEP:SD:CONT 3, ON
Query syntax: LIST:STEP:SD:CONTinue? <NR2>
Query Example: LIST:STEP:SD:CONT? 2
Return Parameter: <bool>
LIST:STEP:SD:VOLTage
This command is used to set the voltage surge for disturbance simulation for a single step in the
list file.
Command syntaxLIST:STEP:SD:VOLTage <NR1>,<NRf>
Parameter 1: 0 ~ 99
Parameter 2: Voltage, unit: V
Example: LIST:STEP:SD:VOLT 2, 30
Query syntax: LIST:STEP:SD:VOLTage? <NR2>
Query Example: LIST:STEP:SD:VOLT? 2
Return Parameter: <NRf>
LIST:STEP:SD:SITe
This command is used to set the initial time the disturbance occurs for a single step in the list