SWEep:MEASure[:SCALar]:VOLTage[:AC]?
This command is used to query the output AC voltage at the sweep maximum power point.
Query syntax: SWEep:MEASure[:SCALar]:VOLTage[:AC]?
Return parameter: <NRf>
Return parameter unit: V
SWEep:MEASure[:SCALar]:CURRent[:AC]?
This command is used to query the output AC current at the sweep maximum power point.
Query syntax: SWEep:MEASure[:SCALar]:CURRent[:AC]?
Return parameter: <NRf>
Return parameter unit: A
SWEep:MEASure[:SCALar]:POWer[:AC][:REAL]?
This command is used to query the output active power at the sweep maximum power point.
Query syntax: SWEep:MEASure[:SCALar]:POWer[:AC][:REAL]?
Return parameter: <NRf>
Return parameter unit: W
SWEep:MEASure[:SCALar]:POWer[:AC]:APParent?
This command is used to query the output apparent power at the sweep maximum power point.
Query syntax: SWEep:MEASure[:SCALar]:POWer[:AC]:APParent?
Return parameter: <NRf>
Return parameter unit: VA
SWEep:MEASure[:SCALar]:POWer[:AC]:PFACtor?
This command is used to query the power factor at the sweep maximum power point.
Query syntax: SWEep:MEASure[:SCALar]:POWer[:AC]:PFACtor?
Return parameter: <NRf>
Return parameter unit: None
SWEep:MEASure[:SCALar]:FREQuency?
This command is used to query the output frequency at the sweep maximum power point.
Query syntax: SWEep:MEASure[:SCALar]:FREQuency?
Parameter: None
Return parameter: <NRf>
Return parameter unit: Hz