EasyManua.ls Logo

BLACKMER LB361B - General Information; Compressor Data

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAFETY DATA
588/A page 2/24
Flammable gas can
cause death, serious
personal injury or
property damage
FLAMMABLE GAS AND/OR LIQUID CAN
FORM EXPLOSIVE MIXTURES WITH AIR
CAUSING PROPERTY DAMAGE,
SERIOUS PERSONAL INJURY OR DEATH
Hazardous pressure
can cause serious
personal injury or
property damage
FAILURE TO RELIEVE SYSTEM
PRESSURE PRIOR TO PERFORMING
COMPRESSOR SERVICE OR
MAINTENANCE CAN CAUSE SERIOUS
PERSONAL INJURY OR PROPERTY
DAMAGE.
Hazardous
machinery can
cause serious
p
ersonal in
j
ur
y
.
FAILURE TO DISCONNNECT AND
LOCKOUT ELECTRICAL POWER OR
ENGINE DRIVE BEFORE ATTEMPTING
MAINTENANCE CAN CAUSE SEVERE
PERSONAL INJURY OR DEATH
Hazardous voltage.
Can shock, burn or
cause death.
FAILURE TO DISCONNNECT AND
LOCKOUT ELECTRICAL POWER
BEFORE ATTEMPTING MAINTENANCE
CAN CAUSE SHOCK, BURNS OR
DEATH
Hazardous or toxic
fluids can cause
serious injury.
IF HANDLING HAZARDOUS OR TOXIC
FLUIDS, SYSTEM MUST BE FLUSHED
AND DECONTAMINATED, INSIDE AND
OUT, PRIOR TO PERFORMING SERVICE
OR MAINTENANCE
Hazardous pressure
can cause serious
personal injury or
property damage
DISCONNECTING FLUID OR PRESSURE
CONTAINMENT COMPONENTS DURING
COMPRESSOR OPERATION CAN
CAUSE SERIOUS PERSONAL INJURY,
DEATH OR MAJOR PROPERTY
DAMAGE
Hazardous gases
can cause property
damage, personal
in
j
ur
y
or death
EXPLOSIVE GAS CAN CAUSE
PROPERTY DAMAGE, PERSONAL
INJURY, OR DEATH.
Extreme Heat can
cause personal injury
or property damage
EXTREME HEAT CAN CAUSE
PERSONAL INJURY OR PROPERTY
DAMAGE
GENERAL INFORMATION
Compressor Data
The models listed are single-stage, vertical, air-cooled reciprocating style compressors with single acting cylinders.
Single-Seal Models
Double-Seal Models
LB161B
LB162B
LB361B
LB362C
LB601B
LB602B
Minimum / Maximum RPM * 350 / 825 350 / 825 350 / 790
Reduce maximum speeds by 9% for continuous duty operation.
Displacement
@ min rpm - CFM (m
3
/hr)
@ max rpm - CFM (m
3
/hr)
7.16 (12.2)
16.9 (28.7)
15.3 (26.0)
36.0 (61.2)
27.2 (46.3)
61.5 (104.5)
Max. BHP (kw) 10 (7.5) 15 (11) 40 (30)
MAWP - psia (kPa) 350 (2,413)
Maximum Discharge Temperature
350°F (176°C)
Rotation Direction Bi-Directional
Table 1 - Compressor Data

Other manuals for BLACKMER LB361B