DECLARATIONS
588/A page 22/24
DECLARATION OF CONFORMITY
As defined by the ATEX Directive 94/9/EC
Blackmer, A Dover Company
113 Neck Road
Ward Hill, MA 01835
United States of America
Herewith we declare that all Blackmer LB and HD
compressor product lines to which this declaration
relates are in conformity with the provisions of the
ATEX Directive 94/9/EC as of 01 July 2003. This
equipment is a reciprocating compressor for liquefied
gas transfer or gas compression applications. This
device is not intended to act as a safety accessory.
Applied Harmonized Standards: EN1127-1,
EN13463-1
20 June 2003
Phil Carpenito Date
General Manager
Blackmer Process Systems Group
DECLARATION OF INCORPORATION
As defined by the Machinery Directive 98/37/EC
Blackmer, A Dover Company
113 Neck Road
Ward Hill, MA 01835
United States of America
Herewith we declare that all Blackmer LB and HD
compressor product lines to which this declaration relates
are in conformity with the provisions of the Machinery
Directive, 98/37/EC. The above equipment is a
reciprocating compressor designed for liquefied gas
transfer or gas compression applications. This device is
not intended to act as a safety accessory.
This component must not be operated until the machine
into which it is incorporated has been declared in
conformity with the provision of the directive.
Applied Harmonized Standards: EN1012-1, EN292
20 June 2003
Phil Carpenito Date
General Manager
Blackmer Process Systems Group
ATEX/ Machinery Directive Notifications:
Maximum Surface Temperature: It is the end user’s responsibility to ensure the compressor does not exceed the
temperature limits. Closed inlet or outlet valves can result in excess compressor surface temperature
conditions.
Intended Use: Blackmer compressors are intended for use in liquefied gas transfer or gas compression
applications. The compressor must be operated in systems, with gasses and at conditions for which it is
specifically designed and sized.
Possible Misuse Warning: The compressor must only be installed in systems designed for its intended use.
Mechanical Ignition Sources: Guards, intended to protect from personal injury from rotating components, must be
fabricated from ATEX compliant materials to prevent a potential ignition source. The compressor and its
drive system must be properly grounded to prevent electrostatic discharge. The compressor has internal
parts that rub together. These parts require proper viscosity lubricant to lubricate the rubbing surfaces.
Compressor must be properly maintained and lubricated, see IOM (Installation, Operation, & Maintenance
Instructions) for service information.
Sound Measurements: Sound Levels for gas compression equipment vary greatly, depending on operating
conditions, piping system design, foundation design, etc. You can expect the following sound levels when
operating a Blackmer compressor at its’ maximum rated speed and discharge pressure. Sound levels are
measured at 1 meter from the compressor and 1.6 meters from the foundation per European Machinery
Directive 98/37/EC. Maximum Noise Level: 85 dba
Equipment Marking: All compressor models are classified Group II category 2, Gas and have a temperature limit
of 176 °C. Compressors are marked “Ex II 2 G 176 °C MAX ”