6060
Error 2 - leak 1 • Check if there is water in base cabinet; if there is, trigger
kitchen or apartment fuse in the building’s electrical installation
2 • Disconnect power supply
• Check for water in the system? (View through rear ventilation
slits; tilt to allow any water to run out of slits)
• If there is none,
o reconnect power supply after 15 minutes and press 'OK' on
the display to confirm malfunction
o Operate system and dispense 2 litres of each water type (hot,
sparkling and still) and wait 15 minutes. Then inspect for any
leaks in the base cabinet or error again on the display
• If there are leaks, contact BLANCO Customer Service
Error 3 - mixer tap
communication
1 • Check whether the mixer tap cable is plugged in properly on
the water conditioning unit rear, press the plug in again more
firmly or remove it and re-insert
2 • Disconnect power supply
• Reconnect power supply after 5 minutes
3 • Is there LED or halogen lighting in or around the installation
site? If there is, disconnect it from the mains in the event of a
malfunction
• Press 'OK' on the display to confirm malfunction
4 • Check mixer tap cable for damage; if damaged, contact
BLANCO Customer Service
5 • Contact BLANCO Customer Service
Error 4 - hardware error 1 • Press 'OK' on the display to confirm malfunction
2 • Contact BLANCO Customer Service
Error 5 - fill level control
implausible
1 • Press 'OK' on the display to confirm malfunction
2 • Disconnect power supply
• Reconnect power supply after 5 minutes
3 • Contact BLANCO Customer Service
Error 6 - hardware error 1 • Press 'OK' on the display to confirm malfunction
2 • Contact BLANCO Customer Service
Error 7 - fan sensor 1 • Press 'OK' on the display to confirm malfunction
2 • Disconnect power supply
• Reconnect power supply after 5 minutes
3 • Contact BLANCO Customer Service
Error 8 - cooling sensor 1 Press 'OK' on the display to confirm malfunction
2 • Disconnect power supply
• Reconnect power supply after 5 minutes
3 • Contact BLANCO Customer Service