EasyManuals Logo

Blodgett 961 Installation And Operation Manual

Blodgett 961
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
34
Gasanschluss und Erste Inbetriebnahme
Einbau
Gasart
Einlaßdruck
(in mBar)
Brennerdruck
(in mBar)
Düsend-
urchmesser
(in mm)
Luftö󰀨nung
(in mm)
Sparbrennerd-
üse
(in mm)
Normaler
Gasanschluß
in kW (Hi)
901
G25 25 18 2.1 4 0.53 6.4
G20 20 12 2.1 4 0.53 6.4
G20/G25 20/25 ~ 1.75 8 0.53 6.4
G30 30/50 17 1.4 4 0.29 6.4
G31 30/37/50 24 1.4 4 0.29 6.4
911
G25 25 18 2.05 4 0.53 5.9
G20 20 12 2.05 4 0.53 5.9
G20/G25 20/25 ~ 1.75 8 0.53 5.9
G30 30/50 17 1.3 4 0.29 5.9
G31 30/37/50 24 1.3 4 0.29 5.9
911P
G25 25 18 2.35 4 0.53 7.9
G20 20 12 2.35 4 0.53 7.9
G20/G25 20/25 ~ 1.9 8 0.53 7.9
G30 30/50 17 1.5 4 0.29 7.9
G31 30/37/50 24 1.5 4 0.29 7.9
961-P, 966, 981
G25 25 18 3.25 4 0.53 14.6
G20 20 12 3.25 4 0.53 14.6
G20/G25 20/25 ~ 2.9 8 0.53 14.6
G30 30/50 17 2.1 4 0.29 14.6
G31 30/37/50 24 2.1 4 0.29 14.6
951, 961
G25 25 18 2.8 10 0.53 11.1
G20 20 12 2.8 10 0.53 11.1
G20/G25 20/25 ~ 2.5 10 0.53 11.1
G30 30/50 17 1.85 4 0.29 11.1
G31 30/37/50 24 1.85 4 0.29 11.1