48
Collegamento al Gas e Avviamento Iniziale
Installazione
Tipo di
Gas
Pressione
Ingresso
mbars
Pressione
Bruciatore
mbars
Diametro
Iniettore
mm
Apertura Aria
mm
Iniettore,
Pilota
mm
Erogazione
Standard
kW (Hi)
1048BL, 1060BL
G25 25 12 3.35 9 0.53 25
G20 20 8 3.35 22 0.53 25
G20/G25 20/25 ~ 2.8 10 0.53 25
G30 30/50 17 2.05 30 0.29 25
G31 30/37/50 24 2.05 30 0.29 25
1048B, 1060B
G25 25 12 3.9 9 0.53 35
G20 20 8 3.9 22 0.53 35
G20/G25 20/25 ~ 3.2 10 0.53 35
G30 30/50 17 2.3 30 0.29 35
G31 30/37/50 24 2.3 30 0.29 35