EasyManua.ls Logo

Blodgett BLCT-6E - Page 38

Blodgett BLCT-6E
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Error Code 12
The heat sink for the solid state relay is too hot because the temperature has
risen above 120°C/248°F. Let it cool off for 20-30 minutes and then retry.
Steps
Check list
Solution
1 Go to the test menu (Main Alarm) to
see which information is displayed.
2 Check the cable and the cable plugs,
and then tighten the solid state relay.
3
-
Clean the intake filter.
4
-
Change the overheating
sensor.
Error Code 13
The temperature of the top heating element of the steam generator has risen
above 130°C/266°F.
Steps
Check list
Solution
1
Go to the test menu (steam generator)
The steam generator may
to see which information the computer
have to be descaled.
displays.
2
Check the cable and the cable plugs.
Change the plug if
necessary.
3
Test the sensor using an ohmmeter, and
If no, change the sensor.
check whether the value matches the
value in the table.
4
A dry fire occurred because the sensor
gave a false water level reading.
Water level tube may be
dirty.
SERVICE MANUAL 39

Other manuals for Blodgett BLCT-6E

Related product manuals