Troubleshooting
Error Code 26
The ClimaOptima sensor signals outside of the active area.
Steps
Check list
Solution
1 Go to the test menu to see which
information the computer displays.
2 Check the cable and the cable plugs
and change the plug if necessary,
and then test if the sensor is working.
3 Check the ClimaOptima sensor in the
test menu, and replace it if necessary,
and then test if the sensor is working.
Error Code 27
ClimaOptima calibration could not be completed. A step took too long.
Steps
Check list
Solution
1 Go to the test menu to see which
information the computer displays.
2
The jet may be clogged & check that the
Restart the calibration
steam jet solenoid is working properly.
process. The oven must be
cold.