Installation
10
Supply Water and Plumbing
WATER CONNECTION
NOTE: Must use COLD WATER ONLY.
A shut off valve is to be provided adjacent to the
oven.
WARNING!!
Operating the appliance without a water
regulator installed will invalidate your warĆ
ranty.
This product must be installed by a licensed
Plumber or Gas Fitter when installed within the
Commonwealth of Massachusetts.
DRAIN CONNECTION
The drain should be run to an open floor drain
avoiding flexible hose that could sag and allow
trapped water to accumulate.
Specific water/drain connection for City of Los
Angeles
1. Each drain line from the appliance shall be
routed without dips or sags to terminate above
the flood level rim of an approved indirect waste
receptor.
2. The appliance shall be installed in accordance
with the manufacturer's printed instructions
and the LAPC and LAMC, 1999 editions.
3. A backflow protection device may be required
by local codes. If so, install on the potable water
system directly ahead of the appliance. The
backflow protection device shall be any of the
following: an approved pressure type vacuum
breaker installed at least 12" above the highest
point of use, a double check valve backflow preĆ
venter or a reduced pressure principal backflow
preventer.

Other manuals for Blodgett HV-100EM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Blodgett HV-100EM and is the answer not in the manual?

Blodgett HV-100EM Specifications

General IconGeneral
BrandBlodgett
ModelHV-100EM
CategoryConvection Oven
LanguageEnglish

Related product manuals