64
Manuale del proprietario
INFORMAZIONI TECNICHE
Modello Dimensioni L×P×H Peso Alimentazione Alimentazione elettrica
con messa a terra
Pro 400B-HR 230V 225×466×460 mm 29 kg 530 W 230V, 50-60 Hz
120V 8.9×18.3×18.1 “ 64 lbs 6 Amp 120V, 60 Hz
Pro 400C-HF 230V 225×466×460 mm 29 kg 530 W 230V, 50-60 Hz
120V 8.9×18.3×18.1 “ 64 lbs 6 Amp 120V, 60 Hz
Pro 400C-HR 230V 225×466×460 mm 29 kg 530 W 230V, 50-60 Hz
120V 8.9×18.3×18.1 “ 64 lbs 6 Amp 120V, 60 Hz
Pro 400BC-HR 230V 225×466×460 mm 29 kg 530 W 230V, 50-60 Hz
120V 8.9×18.3×18.1 “ 64 lbs 6 Amp 120V, 60 Hz
Pro 400CV-HR 230V 225×466×470 mm 29 kg 530 W 230V, 50-60 Hz
120V 8.9×18.3×18.5 “ 64 lbs 6 Amp 120V, 60 Hz
Pro 400BCV-HR 230V 225×466×470 mm 29 kg 530 W 230V, 50-60 Hz
120V 8.9×18.3×18.5 “ 64 lbs 6 Amp 120V, 60 Hz
Pro 600C-HF 230V 225×466×460 mm 29 kg 720 W 230V 50-60 Hz
Pro 600CV-HR 230V 225×466×470 mm 29 kg 720 W 230V 50-60 Hz
Requisiti dell’acqua di mandata al depuratore
Modello
Temperatura
Pressione del
flusso
dell’acqua di
mandata
Pressione
TDS
(Total Disolved
Solids) [ppm]
Conduttività
[µS/cm, 25 °C
(77 °F)]
Durezza
Ferro Fe
(+2)
/
Fe
(+3)
[mg/l]
Torbidità [FNU]
Pro 400B-HR
Pro 400BC-HR
Pro 400BCV-HR
230V 2-30 °C 2-10 bar
0.2-1 MPa
> 10
l/min
< 7500 < 13 000 < 20 °dH < 1.5/
< 0.3
< 0.5
120V 36-86 °F 29-145
psi
> 2.6
gal/min
< 20.9
grains/gal
Pro 400C-HF
Pro 400C-HR
Pro 400CV-HR
230V 2-35 °C 2-10 bar
0.2-1 MPa
> 10
l/min
< 1500 < 2000 < 20 °dH < 1.5/
< 0.3
< 0.5
120V 36-95 °F 29-145
psi
> 2.6
gal/min
< 20.9
grains/gal
Pro 600C-HF
Pro 600CV-HR
230V 2-35 °C 2.5-10 bar
0.25-1
MPa
> 10
l/min
< 1500 < 2000 < 20 °dH < 1.0/
< 0.3
< 0.5

Table of Contents