EasyManua.ls Logo

BOC Smootharc Elite MIG 451 Progress Pulse - General Operating Problems; Interface for Mechanised Welding

Default Icon
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rectifying faults
General operating problems
38
099-004839-BOC01
10.11.2009
7.4 General operating problems
Problem Possible cause > remedy
Machine control without displaying the signal
lights after switching on
Phase failure > check mains connection (fuses)
no welding performance Phase failure > check mains connection (fuses)
various parameters cannot be set Entry level is blocked > disable access lock (see
chapter entitled "key switch", if available)
7.4.1 Interface for mechanised welding
WARNING
No function of the external shut-down devices (emergency stop switch)!
If the emergency stop circuit has been realised using an external shut-down device via
the interface for mechanised welding, the device must be set for this setup. If this is not
observed, the power source will ignore the external shut-down devices and will not shut
down!
Disconnect jumper 1 on PCB T320/1 or M320/1!

Table of Contents