Allgemeines.pm6.5 - USA
Page 1.7
General
BOGE Operating instructions for S 40-2...S 341 / SF 40-2...SF 220 series screw compressors
Intended use
Inadmissible use
BOGE S series screw compressor, including its additional equipment, is
exclusively intended for the compression of air.
The air taken in must not contain any explosive or chemically instable gases
or vapors.
Do not exceed specified final compression temperature.
BOGE screw compressors are designed for stationary operation.
Ensure that they are only installed and operated in dry and clean rooms.
Operation, control and maintenance are designed to be executed by trained
and authorized operators.
Never direct the produced compressed air towards persons. Danger to life!
WARNING!
Statement concerning the use of this equipment for breathing air and/
or aqua lung service. If the model number on this air compressor contains
the letters "BAP", the compressor is suitable for use in breathing air services.
In the absence of such a designation, the compressor is NOT considered as
capable of producing air of breathing quality. For a compressor to be capable
of use in breathing air services it must be fitted with additional specialized
equipment to properly filter and/or purify the air to meet all applicable federal,
state and local laws, rules, regulations and codes, such as, but not limited
to, OSHA 29 CFR 1910.134, Compressed Gas Association Commodity
Specification G-7, 1-1966, Grade D Breathing Air and/or Canadian Standards
Association. Should the Purchaser and/or User fail to add such specialized
equipment and proceeds to use the compressor for breathing air service,
the Purchaser/User assumes all liability resulting therefrom without any re-
sponsibility or liability being assumed by BOGE COMPRESSORS.
The Purchaser is urged to include the above provision in any agreement for
any resale of this compressor.
This BOGE screw compressor is not explosion protected. Do not operate in
explosive areas!
Do not operate compressor in rooms in which extreme dust, toxic or flam-
mable vapors and gases may occur.
The following is not permitted:
Exceeding the final compression pressure indicated on the type plate.
Altering the safety devices and cladding or placing them out of operation.
Removing or painting over signs and symbols on the compressor.
Operation of the compressor by unauthorized or untrained persons.
Operation of the compressor with removed cladding or safety devices.
1. 2 Introduction

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Boge S Series and is the answer not in the manual?

Boge S Series Specifications

General IconGeneral
TypeScrew Compressor
DriveDirect drive
CoolingAir / Water
Pressure13 bar
Noise Level78 dB(A)