INSTALLATION INSTRUCTIONS
21
Checklist
Check List
Use this list to check the installation.
Unit
All equipment ordered by the customer is installed.
The unit is level and secure.
The water supply line has been flushed to clear swarf and debris and is free of leaks.
The tank is free of foreign matter and debris. The water isolating tap is turned ON.
Water drainpipe work is completed and sealed.
The fan assembly is correctly located and the fan blade spins freely in the venturi.
The mains and control wiring are complete and the circuit breaker is turned ON.
The water basin fills with water and the float valve closes correctly when the water level
is below the overflow level.
The water pump operates correctly when turned ON at the controller.
Bleed rate is set to suit local water conditions.
The fan operates through the entire speed range.
Water distribution is even with the filter pads fitted and the air conditioner operating
pump and fan.
All Controller functions for the appliance operate
Ductwork and general
All roof penetrations are fully sealed and watertight.
All ductwork is completed to plan, correctly supported and airtight, with no bend tighter
than 1.5 x the ductwork diameter.
Air distribution checked, dampers are adjusted and all outlets correctly adjusted and
wiped clean.
Man hole cover replaced.