1-866-771-2663 | Page 3
• Combustible material should not be within 72 inches of the top of the unit, or within 48 inches
around the entir
e unit.
•
Keep the appliance ar
ea clear and fr
ee fr
om combustible material, gasoline and other ammable
vapors and liquids.
•
If the ame goes out while bur
ning, tur
n the gas valve of
f. Wait 5 minutes before r
epeating the initial
lighting pr
ocedure. Once you have a ame started, hold down the control knob for 1 minute.
•
Do not add water into the unit.
• Do not operate unit if any part has been under water. Call a service technician to replace any
damaged parts should this occur.
• Do not disconnect any part while unit is in use.
• Do not store a spare pr
opane tank on or near this unit.
•
If the heating unit is indoors, detach the propane tank and leave outdoors.
• Do not operate on a boat or vehicle. This unit must be used on a at surface and outdoors ONLY.
• Always remove protective cover befor
e operating (if applicable).
•
Do not set the protective cover over the unit until it is turned of
f and completely cooled down.
•
Check for leaks after not using the unit for long periods of time.
• Children should never operate this unit. Children must be supervised while near this unit.
• Keep gas tank at least 5 feet away from unit when lit. (if external tank)
• The maximum gas supply pressure is 250psi.
• All installation and repair should be done by a qualied professional. This unit should be
inspected annually and cleaned regularly.
• Inspect all elements of this heating unit before each use. If there is damage, the burner must be
replaced.
• Keep the hose out from any pathways to eliminate any accidental damage. (if external tank)
• Be aware of the hazards of high temperatur
es and stay away from the unit to avoid any burns or
injury.
•
The gas supply tank should be constructed and marked with the specications for the LP gas tanks
of the U.S. Department of Transportation or the National Standard of Canada CAN/CSA-B339, LP gas
tanks, spher
es and tubes for Transportation of Dangerous Goods; and Commission.
•
The LP gas tank must have a listed overlling prevention device and a QCCI or Type I, (CGA810) LP
gas tank connection.
• This heating appliance should not be used on plastic or articial wood desks.
• Children and adults should be alerted to the hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition.
• Young children should be car
efully supervised when they are in the area of the appliance.
•
Clothing or other ammable materials should not be hung from the appliance or placed on or
near the appliance.
• Any guard or other protective device r
emoved for servicing the appliance shall be replaced
prior to operating the appliance.
•
Installation and repair should be done by a qualied service person. The appliance should be
inspected before use and at least annually by a qualied service person. More fr
equent cleaning
may be required as necessary. It is imperative that the control compartment, burners and
circulating airways of the appliance are kept clean.
IF APPLICABLE:
• Allow heating item to cool completely before placing on lid.
• DO NOT use heating item while lid is installed. Always remove the lid while heating item is in use.