7.3.2 Recovery
i During the recovery phase ACS 611 automatically
empties the service hoses and separates the
extracted oil from the refrigerant which flows into
the oil bottle.
i The pressure in the vehicle air conditioner must be
checked prior to and during the recovery phase.
! Observe ACS 611 menu prompting.
<Recovery> key
1. Call up start screen.
2. Press <Recovery>.
SELECT PORTS?
1 HP & LP PORTS
2 HP PORT
3 LP PORT
3. Select <1>,<2> or <3>; confirm with E.
"ACS 611 first performs a self-cleaning process, then
the recovery phase.
i Return with <Stop>.
7.3.3 Vacuum
i Make sure recovery has been performed before
generating the vacuum.
! Observe the ACS 611 menu prompting.
1. Call up start screen.
2. Press <Vacuum>.
3. Enter duration of vacuum generation with <09>,
z v and confirm with E.
"ACS 611 performs vacuum phase.
i Return with <Stop>.
7.4 Automatic service
i
This function enables the automatic performance of
the service phases Recovery, Vacuum and Filling.
i Service parameters (vacuum generation time, filling
quantity and type of refrigerant and fresh oil) can be
taken from the database and used for the "Automatic
Service".
! The service parameters (vacuum generation time,
recharge quantity, oil and refrigerant type) can be
found in the owner's manual or the vehicle repair
manual and must be observed.
! For vehicles with only one service connection the
service phase "Filling" should be performed in the
"Manual service" mode.
! For vehicles with only one service connection the
manufacturer's recommended procedure must be
followed.
! Observe the ACS 611 menu prompting.