10.7 Service data report
10.7.1 Activate/deactivate consumption
R134a report
i ACS 611 can store the R134a consumption data
during all filling and evacuation processes.
! Can be deactivated by customer service only.
10.7.2 Report printout
! The data storage of ACS 611 may contain more data
than can be printed on one paper roll (printer).
! Observe the ACS 611 menu prompting.
1. Press <MENU>.
2. Select "REPORT MANAGEMENT"" with o u and
confirm withE.
3. Select "PRINT REPORT"" with o u and confirm with
E.
The stored reports are displayed.
4. Select report with o u and confirm with E.
"Report is printed.
i Return with <Stop>.
i It is recommended to print or delete the stored
reports at least once a week.
11. Maintenance
11.1 Spare and wearing parts
Description Order number
Combo filter
SP00100001
Vacuum pump oil
SP00100086
Roll of paper for printer
SP00100087
Service hose (HP) 2,5 m
SP00100029
Service hose (HP) 5 m
SP00100035
Service hose (LP) 2,5 m
SP00100030
Service hose (LP) 5 m
SP00100036
Quick-release coupling (HP)
SP00100083
Quick-release coupling (LP)
SP00100082
Used oil bottle
SP00100060
Fresh oil bottle
SP00100059
UV dye bottle
SP00100061
Adapter set 2,5 m - 5 m
SP00100075
11.2 Maintenance interval
Description Period
Calibration of fresh and used
oil scales
Once a year or on change of
fresh oil type
Vacuum pump oil replacement
and system leak test
see display (10h)
Replacement of combo filter see display (150kg)
! Never perform any maintenance work which is not
expressly recommended in this Section.
! Contact customer service if components have to be
replaced other than in the course of maintenance
work.