EasyManua.ls Logo

Bosch MC 400 User Manual

Bosch MC 400
92 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
[de] Installationsanleitung für das Fachhandwerk ................................................. 2
[en] Installation instructions for skilled labour.................................................... 11
[es] Manual de instalación para el técnico especializado...................................... 20
[fl] Installatiehandleiding voor de installateur ................................................... 29
[fr] Notice d’installation pour le professionnel................................................... 38
[it] Istruzioni per l'installazione per tecnico specializzato.................................... 48
[nl] Installatie-instructie voor de installateur ..................................................... 58
[pt] Instruções de instalação para técnicos especializados .................................. 68
[zh] уъӪઈᆹ㻵䈤᰾Җ ........................................................................... 77
MC 400
6 720 809 449-00.1O
EMS 2
EMS plus
EMS
6 720 819 669 (2016/05)

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Bosch MC 400 and is the answer not in the manual?

Bosch MC 400 Specifications

General IconGeneral
BrandBosch
ModelMC 400
CategoryControl Unit
LanguageEnglish

Summary

Key to Symbols and Safety Instructions

Key to Symbols

Explains warning symbols and their meanings.

General Safety Instructions

Provides essential safety guidelines for installation and use.

Product Details

Important Usage Information

Details crucial information for proper use and communication protocols.

Function Description

Explains the basic principle of operation and cascade control.

Basic Principle

Explains the fundamental operation of modulating cascade output.

Time Limits

Covers time limitations for switching heat sources.

Control Strategies

Serial Standard Cascade

Describes sequential activation of heat sources based on wiring order.

Serial Optimised Cascade

Outlines control based on burner runtime for balanced usage.

Serial Cascade with Peak Load Coverage

Details strategy for covering base load and peak demand.

Parallel Cascade

Explains parallel activation for heat sources with similar modulation.

Output Control

Describes controlling output via 0-10V signal.

Flow Temperature Control

Explains controlling based on required flow temperature via 0-10V.

Pump Pre-run

Covers the pump's pre-run period before burner ignition.

Setting the Coding Card

Scope of Delivery

Lists the items included in the product package.

Specifications

Provides technical data and compliance information.

Additional Accessories

Lists optional accessories for system expansion.

Cleaning

Instructions for cleaning the device enclosure.

Mounting

Installation of Temperature Sensor on the Low Loss Header

Details the placement of temperature sensors on the low loss header.

Electrical Connection

Covers all aspects of connecting the module electrically.

Connecting the BUS Connection and Temperature Sensor (Extra-Low Voltage Side)

Explains BUS and temperature sensor wiring for the low-voltage side.

Connecting the Power Supply, Pump and Mixer (Mains Voltage Side)

Details wiring for power supply, pumps, and mixers on the mains voltage side.

Connection Diagrams with System Schematics

Overview of the Terminal Assignment

Commissioning

Setting the Coding Card

Instructions for setting the coding card for system configuration.

System and Module Commissioning

Step-by-step guide for commissioning the system and modules.

Settings for Systems with a Cascade Module in the BUS System

Configuration steps for systems with one cascade module on the BUS.

Settings for Systems with 2 or More Cascade Modules in the BUS System

Configuration steps for systems with multiple cascade modules on the BUS.

Status Display for the Heat Source on the Subordinate Cascade Module

Details LED indicators for heat source status on subordinate modules.

Cascade Settings Menu

Diagnosis Menu

Eliminate Fault

Status Indicator on the Individual Installed or Higher-Level Cascade Module

Explains status indicators for master or individual cascade modules.

Status Indicator on the Lower-Level Cascade Module

Explains status indicators for slave cascade modules.

Environment / Disposal

Installation

Installation

General instructions for mounting the module.

Installation of Temperature Sensor on the Open Header

Details on installing temperature sensors on the open header.

Electrical Connection

Covers all aspects of connecting the module electrically.

Connecting the BUS Connection and Temperature Sensor (Low-Voltage Side)

Explains BUS and temperature sensor wiring for the low-voltage side.

Connecting the Power Supply, Pump and Mixer (Mains Voltage Side)

Details wiring for power supply, pumps, and mixers on the mains voltage side.

Connection Diagrams with System Schematics

Overview of the Terminal Assignment

Commissioning

Setting the Coding Card

Instructions for setting the coding card for system configuration.

System and Module Commissioning

Step-by-step guide for commissioning the system and modules.

Settings for Systems with a Cascade Module in BUS System

Configuration steps for systems with one cascade module on the BUS.

Settings for Systems with 2 or More Cascade Modules in BUS System

Configuration steps for systems with multiple cascade modules on the BUS.

Status Display for the Heat Source on the Subordinate Cascade Module

Details LED indicators for heat source status on subordinate modules.

Cascade Settings Menu

Diagnosis Menu

Eliminate Fault

Status Indicator on the Individual Installed or Master-Cascade Module

Explains status indicators for master or individual cascade modules.

Status Indicator on the Slave-Cascade Module

Explains status indicators for slave cascade modules.

Environment / Disposal