EasyManua.ls Logo

Bosch ACS 810 - Software and Database Updates; Printer Paper Replacement; Purge Valve Check

Bosch ACS 810
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance | ACS 810 | 61 | en
1 689 989 601 2020-12-01| Robert Bosch GmbH
12.6 Software update
12.6.1 Firmware
i The firmware (software) can be updated by way of
a PS2 stick. Further information can be obtained
from customer service.
12.6.2 Vehicle database
i The vehicle database can be updated annually by
way of a PS2 stick. Further information can be
obtained from customer service.
! Do not switch off ACS 810 during update process.
! Observe the ACS 810 menu prompting.
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
The message ENTER CODE 0000 is displayed.
3. Enter code 2222 and confirm with E.
4. Select "DATABASE UPDATE" with o u and confirm
with E.
INSERT THE KEY is displayed.
5. Remove plastic cover (input PS2 stick) between
menu key and stop key.
6. Insert PS2 stick.
7. Activate or deactivate with o u and confirm with E.
The update is performed.
" Data base is updated.
i Return with <Stop>.
12.7 Replacing printer paper
! Avoid excessive force so as not to damage the
printer cover.
1. Open the printer cover.
2. Remove old printer paper roll.
3. Fit new printer paper roll.
459897_10Rf
1
Fig. 7: Replacing printer paper
1 Printer paper
4. Close the printer cover.
i To cut the printer paper correctly, pull the paper
towards the tear bar from one side to another.
12.8 Periodic check of the non-condensable
gas purge valve
CAUTION: Only qualified technicians who
are authorized to use refrigerants may
carry out this procedure.
Wear personal protective equipment
(glasses and gloves).
Do not go in front of the discharge flow.
The valve does not require adjustment or
lubrication. Do not tamper with it in any
way.
1
Fig. 8: Periodic check of the non-condensable gas purge valve
1 Non-condensable gas purge valve
i To ensure that the valve remains in good working
condition, periodically make it trip by pulling the
metal ring at the top.
i While doing this, make sure that the pressure in the
cylinder is at least 8–10 bar.
i The valve should open sharply and then close
firmly as soon as the metal ring is released.
! This action must be quick, and do not repeat it
until only non-condensable gas is purged, with no
refrigerant.
i The frequency depends on the valve condition,
and specifically on its cleanliness, which normally
depends on whether there are residues in the
cylinder or not.

Table of Contents