Contacts
Inputs
The analog inputs can be used as digital or analog
contacts. For analog use, resistance values can be
specified to check for cable breaks and short-circuits.
Relay outputs
The relay outputs offer the following functions:
• The outputs can operate with potential free contacts
for external power supply (dry mode).
• The outputs can operate using the internal voltage of
power supply (wet mode).
• Only ohm resistive loads can be connected to the
relay.
• Inductive loads must be bypassed via recovery
diodes. These diodes (IN4004) are enclosed.
General instructions
• All access equipment should be mounted within a
"secured area".
• Detailed connection conditions are specified in the
operating manual!
• After purchase, primary AC power must be carried
out by a licensed electrician.
Technical specifications
Hardware 16 or 8 or null relay outputs - with ohm load:
- max. switching voltage: 30 V DC
- max. switching current: 1,25 A
16 or 8 analog inputs
Tamper switch
Temperature 0°C to +45°C (32° F to 113° F)
Power supply - 10 or 30 V DC, max. 60 VA
Available for external devices: 55 VA
- or via the AMC2
Protection
class
IP 30
Housing Base: PPO (UL 94 V-0)
Upper: Polycarbonate (UL 94 V-0)
Color White
Dimensions WxHxD: 232 x 90 x 46 mm (9.13 x 3.54 x 1.81 in.)
Weight Approx. 0.4 kg (0.88 lb)
Type Rail mounting
Ordering information
AMC2 8I-8O-EXT
8 input/output extension board, up to three per AMC,
can be combined with the AMC2 16I-EXT and the
AMC2 16I-16O-EXT
Order number API-AMC2-8IOE
AMC2 16I-16O-EXT
16 input/output extension board, up to three per AMC,
can be combined with the AMC2 16I-EXT and the
AMC2 8I-8O-EXT
Order number API-AMC2-16IOE
AMC2 16I-EXT
16 input extension board, up to three per AMC, can be
combined with the AMC2 16I-16O-EXT and the AMC2
8I-8O-EXT
Order number API-AMC2-16IE