140
Configuration of Recordings
Recording Diagnosis
The channel ‘stateclrl_ok’
of the C 60 can be used for online monitoring of recording status
Content of status bits
C 60 Recording and Telemetry
Internal | BEG/EMS1 CsM | 6/4/2010 | ©
Bosch Engineering GmbH 2009. All rights reserved, also regarding any disposal, exploitation,
reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Motorsport
Bit 8 7 6 5 4 3 2 1
Value 128 64 32 16 8 4 2 1
Name 1 STARTED 1 1 1 BLKOK DATAOK RECORD
Name Bit set Bit cleared
RECORD Measurement data is recorded No measurement data will be
stored because measurement
thresholds are not reached
DATAOK Received data without error Discarding received data
because of wrong timestamps.
Check wiring of SYNC signal.
BLKOK All measurement blocks have
been set up correctly
Some measurement blocks have
not been set up correctly.
STARTED A measurement has been set up A measurement is not set up.
Either no recording configuration
has been found or logger
software upgrade is not activated