6 720 808 869 (2014/06)Compress 3000 DW FOO
Appliance status information | 27
Fig. 24 "Hol" operating mode
Switching on the "Hol" function
▶ Call up the "Hol" function.
▶Press "ok".
The current month flashes on the display.
▶ Use the "+" and "-" buttons to set the month in which the
holiday ends.
▶Press "ok".
The current day flashes on the display.
▶ Use the "+" and "-" buttons to set the day on which the
holiday ends.
▶Press "ok".
The "Hol" function is active.
Deactivating the "Hol" function manually
To deactivate the "Hol" operating mode before the set date:
▶ Call up the "Prog" menu.
▶Press “ok”
▶ Select "man" (manual mode).
The heat pump will start operating and will initiate a
legionella disinfection.
Tank freeze protection
The electric booster heater starts up when the water
temperature in the tank falls below 5 °C and switches off again
when the temperature reaches 8 °C.
5.6.4 "OFF" operating mode
In this operating mode, the appliance is switched off. If
necessary, the electric booster heater is switched on by itself
for the tank anti-freeze protection function.
The legionella disinfection cycle is ensured once per week
according to the schedule, to ensure that the appliance is ready
to be safely used immediately after being set back to any of the
normal operation modes.
Fig. 25 "OFF" operating mode
5.7 "Set" submenu - Settings
You can set various parameters in the "Set" submenu:
•Date
• Prog - timetable operating programing
• Leg - legionella
• Plus - enhanced comfort function
• Hea - heating by electric assistance
•Purg - purge
• Fset - factory settings
Once the appliance is switched back on, the
"Leg" function ( section 5.7.3) is executed
automatically.
In "Hol" mode, the appliance still operates for
12 hours.
The "Hol" operating mode can be set for a
maximum of 4 months.
▶ Check that the date is correct
(section 5.7.1).
▶ The appliance must be connected to the
mains power supply for correctly run the
Holiday mode.