Technical information
25
Compress 7000i AW – 6721830633 (2021/02)
Acoustic performance data with sound insulation at front and back
(accessory)
Table 22 Acoustic performance data – heat pump (three-phase current) with sound insulation at front and back
9.3 Operating range of heat pump without auxiliary
heater
The heat pump switches off at approx. – 20 °C or +35 °C. The indoor
unit or an external heat source then take over the heating and DHW
heating. The heat pump restarts if the outdoor temperature exceeds
roughly – 17 °C or falls below +32 °C. In cooling mode the heat pump
switches off at roughly +45 °C and restarts at roughly +42 °C.
Fig. 22 Heat pump without auxiliary heater
[1] Maximum flow temperature (T0)
[2] Outdoor temperature (T1)
Unit 13 OR-T 17 OR-T
Max. sound power dB(A) 61 62
Max. sound power "quiet operation" dB(A) 56 56
35
45
50
55
60
-30
T1[°C]
T0[°C]
30
25
20
15
10
-20
0-10 10
20 30 40
1
2