Technical information
Compress 7001i AW – 6721835318 (2021/09)
22
Table 15 Detailed sound pressure level of heat pump (alternating current) acoustic covers at front and back (accessories)
Table 16 Detailed sound pressure level, heat pump (alternating current)
Table 17 Detailed sound pressure level of heat pump incl. acoustic covers at front and back (accessories)
Acoustic performance data with sound insulation at front and back
(accessory)
Table 18 Acoustic performance data – heat pump (three-phase current) with sound insulation at front and back
Detailed sound pressure level (max.) 9 OR-S incl. acoustic covers at front and back (accessories)
Clearancem123456810121416
Day >3 m
1)
1) Heat pump more than 3 m from the wall
dB (A) 51 45 41 39 37 35 33 31 29 28 27
<3 m
2)
2) Heat pump closer than 3 m to the wall
dB (A)5448444240383634323130
Night >3 m
1)
dB (A) 47 41 37 35 33 31 29 27 25 24 23
<3 m
2)
dB (A)5044403836343230282726
Detailed sound pressure level (max.) 13 OR-S
Clearancem123456810121416
Day >3 m
1)
1) Heat pump more than 3 m from the wall
dB (A) 56 50 46 44 42 40 38 36 34 33 32
<3 m
2)
2) Heat pump closer than 3 m to the wall
dB (A)5953494745434139373635
Night >3 m
1)
dB (A) 49 43 39 37 35 33 31 29 27 26 25
<3 m
2)
dB (A)5246424038363432302928
Detailed sound pressure level (max.) 13 OR-S incl. acoustic covers at front and back (accessories)
Clearancem123456810121416
Day >3 m
1)
1) Heat pump more than 3 m from the wall
dB (A) 53 47 43 41 39 37 35 33 31 30 29
<3 m
2)
2) Heat pump closer than 3 m to the wall
dB (A)5650464442403836343332
Night >3 m
1)
dB (A) 48 42 38 36 34 32 30 28 26 25 24
<3 m
2)
dB (A)5145413937353331292827
Unit 5 OR-S 7 OR-S 9 OR-S 13 OR-S
Max. sound power dB(A) 58 58 59 61
Max. sound power “quiet
operation”
dB(A) 51 54 55 56