Technical information
29
Compress 7001i AW – 6721835318 (2021/09)
9.5.3 Measurements for temperature sensor
Table 25 Sensor TA4, TL2, TR4, TR5
Table 26 Sensor TC3, TR3
Table 27 Sensor TR1, TR6
9.6 Information on refrigerant
This device contains fluorinated greenhouse gases as refrigerant. The
device is hermetically sealed. You will find the information on the
refrigerant according to the Regulation (EU) No 517/2014 on
fluorinated greenhouse gases in the operating instructions of the device.
Information for the installer: If you refill refrigerant, enter the additional
charge size and the total charge size of the refrigerant in the table
“information on refrigerant” of the operating instructions.
°C r.. °C r... °C r...
– 40 154300 5 11900 50 1696
– 35 111700 10 9330 55 1405
– 30 81700 15 7370 60 1170
– 25 60400 20 5870 65 980
– 20 45100 25 4700 70 824
– 15 33950 30 3790 75 696
– 10 25800 35 3070 80 590
– 5 19770 40 2510 85 503
± 0 15280 45 2055 90 430
°C °C °C °C
– 20 96358 15 15699 50 3605 85 1070
– 15 72510 20 12488 55 2989 90 915
– 10 55054 25 10001 60 2490
– 5 42162 30 8060 65 2084
± 0 32556 35 6536 70 1753 – –
5 25339 40 5331 75 1480
10 19872 45 4372 80 1256 – –
°C °C °C °C
– 20 198500 15 31540 50 6899 85 2123
– 15 148600 20 25030 55 5937 90 1816
– 10 112400 25 20000 60 4943 95 1559
– 5 85790 30 16090 65 4137 100 1344
± 0 66050 35 13030 70 3478 105 1162
5 51220 40 10610 75 2938 110 1009
10 40040 45 8697 80 2492 1156 879