Product Information
Condens 7000 F – 6720871579 (2022/10)
4
HInstallation and conversion
Correct and proper installation and adjustment of the burner and the
control unit are the fundamental requirements for safe and
economical operation of the floor standing boiler.
Only permit an authorised contractor to install the boiler.
Never modify any parts for flue gas routing.
Electrical work must only be carried out by qualified electricians.
▶With open-flue mode: do not cover or reduce the size of ventilation
apertures in doors, windows or walls. If draught-proof windows are
fitted, ensure there is an adequate supply of combustion air.
Use the DHW cylinder exclusively for heating hot water.
Never shut off pressure relief valves!
Water may be expelled at the pressure relief valve of the heating
circuit and DHW pipework during heat-up.
HInspection/maintenance
Heating systems must be regularly maintained.
In that way, you will obtain a high level of efficiency and low fuel
consumption.
You will achieve a high level of operational safety and reliability.
And you will obtain the cleanest possible combustion.
Recommendation for customers: arrange a maintenance and
inspection contract with an authorised contractor, covering an
annual inspection and demand-dependent maintenance.
Maintenance and repairs may only be carried out by an authorised
contractor.
Have any faults immediately rectified to prevent damage to the
system.
The user is responsible for ensuring the heating system is safe and
environmentally compatible.
Only use genuine spare parts! Damage caused by the use of spare
parts not supplied by Bosch is not covered by the warranty.
HDanger posed by explosive and easily flammable materials
Any work on components that carry gas may only be carried out by an
approved contractor.
Never use or store easily flammable materials (paper, thinners, paints
etc.) near the boiler.
HDanger of poisoning
Insufficient ventilation can lead to dangerous flue gas leaks.
Ensure that ventilation or extract air apertures are not reduced or
closed.
Faults should be rectified without delay, otherwise the boiler must
not be operated.
If flue gas enters the installation location, ventilate and vacate the
area and if necessary call the fire brigade.
Inform the system user in writing of the problem and associated
danger.
HDanger of water damage
In the event of severe risk of flooding, shut down the power and fuel
supply to the device before water enters the installation location.
Never use the device if any part of it has been under water.
Immediately get in touch with a qualified service technician to have
the device inspected and have any part of the control system and any
air/gas ratio control valves that have been under water replaced.
HCombustion air/ambient air
The air in the installation location must be free of flammable or
chemically aggressive substances.
Do not store or use any corrosive substances (solvents, adhesives,
chlorinated cleaning agents, etc.) within the vicinity of the heat
source.
Avoid very dusty atmospheres.
HRisk of damage from operating errors
Operator errors can result in personal injury and/or material damage.
Ensure that children never operate this appliance unsupervised or
play with it.
Ensure that only personnel who can operate this appliance correctly
have access to it.
HFurther important notices
Never switch off or interrupt the power supply to the pump in case of
overheating or if the gas supply does not shut down. Instead,
interrupt the gas supply at another point outside of the heating
system.
The flue system must be checked every year. During this inspection,
have a contractor replace any parts that show signs of damage
through corrosion or other causes.
The boiler must be serviced annually by a qualified service provider.
The inspection must include the main burner, the entire flue gas and
air supply system and the ventilation apertures or air inlet openings.
During this inspection, have any parts that show signs of damage
through corrosion or other causes replaced.
Operate the boiler only with mounted and closed casing.
2Product Information
To ensure safe, economical and environmentally responsible use of the
heating system, we recommend that you read the safety instructions and
operating instructions carefully.
These instructions provide the operator of the heating system with an
overview of the use and operation of the boiler.
2.1 Intended use
The Condens 7000 F is designed for use as a floor standing gas
condensing boiler for DHW and central heating.
Only approved gases can be used.
2.2 Declaration of conformity
The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.3 GB Importer
Bosch Thermotechnology Ltd.
Cotswold Way, Warndon
Worcester WR4 9SW / UK

Other manuals for Bosch Condens 7000 F